Reverse Osmosis (RO) Membranes for Water Treatment – High-Rejection, Low-Fouling Elements for Brackish Water, Seawater & Wastewater Reuse
In water treatment, your reverse osmosis membrane is the heart of the system-its performance directly impacts water quality, energy consumption, chemical usage, and operational costs. Poor membrane selection leads to rapid fouling, scaling, low recovery, and frequent replacements. Our high-performance RO membrane for water treatment delivers 99% salt rejection, enhanced fouling resistance, and long service life-engineered for municipal drinking water, industrial process water, seawater desalination, and advanced wastewater reuse. Compatible with all major RO pressure vessels (DOW/FilmTec™, Hydranautics™, Toray™ form factors), our elements offer OEM-equivalent or superior performance at a better value.
COYON supplies six series of industrial reverse osmosis membranes: ultra-low-pressure reverse osmosis membrane elements, low-pressure high desalination rate reverse osmosis membrane elements, brackish water reverse osmosis membranes, high-pressure anti-fouling membrane elements, seawater reverse osmosis membranes, and household mechanical membrane elements.



Benefits of Reverse Osmosis Membranes
Not All RO Membranes Perform the Same-Ours Are Optimized for Real-World Water
* High Salt & Organics Rejection: 99% NaCl rejection ensures consistent permeate quality-even under variable feed conditions.
* Fouling-Resistant Surface: Modified polyamide layer reduces adhesion of colloids, organics, and biofilm.
* Wide pH & Cleaning Tolerance: Operates from pH 2–11; withstands aggressive CIP (cleaning-in-place) protocols.
* Energy-Efficient Design: Lower operating pressure = reduced pump energy (up to 15% savings vs standard elements).
* Consistent Manufacturing: Produced in ISO 9001-certified cleanroom facilities with 100% integrity testing.
* Drop-In Replacement: Exact dimensional match for 400GPD, 8040, 4040, and other industry-standard housings.
RO Membrane Series for Every Water Source
1. BWRO Series – Brackish Water Reverse Osmosis Membranes
* Ideal for: Groundwater, surface water, municipal pretreated water
* Key Features:
- Permeate flow: 2,500–10,000 GPD (400–1600 L/h) per 8040 element
- Salt rejection: ≥99%
- Max pressure: 600 psi
- Applications: Drinking water plants, food & beverage, boiler feedwater, industrial process water
2. SWRO Series – Seawater Reverse Osmosis Membranes
* Ideal for: Ocean water, high-TDS brines (>15,000 ppm)
* Key Features:
- Permeate flow: 5,500–8,500 GPD per 8040 element
- Salt rejection: ≥99%
- Max pressure: 1,200 psi (83 bar)
- Boron rejection: Up to 95% (with specialized variants)
- Applications: Desalination plants, island resorts, offshore platforms
3. NF/RO Hybrid Series – For Wastewater Reuse & Softening
* Ideal for: MBR permeate, secondary effluent, hard water
* Key Features:
- High divalent ion rejection (Ca²⁺, Mg²⁺, SO₄²⁻)
- Moderate monovalent rejection (allows partial salt passage for lower osmotic pressure)
- Excellent organic & color removal
- Applications: Industrial water reuse, laundry recycling, cooling tower makeup


Process flow of RO Membrane
Raw water tank → boosting pump → multi-media filter → scale prevention device → precision filter → first-stage high-pressure pump → first-stage RO (CIP) → intermediate water tank → second-stage high-pressure pump → second-stage RO → product water tank

RO Membrane Technical Comparison Table
| Model | BW30-4040 | BW30-400 | BW30FR-4040 | BW30FR-400 | LP-4040 | LP-8040 |
| GPD(m³/d) | 2400(9.1) | 11000(41) | 2400(9.1) | 11000(41) | 2400(9.1) | 11000(41) |
| Max Input Water Flow | 16gpm(3.63/h) | 80gpm(183/h) | 16gpm(3.63/h) | 80gpm(183/h) | 14gpm(3.23/h) | 80gpm(183/h) |
| Average Salt Rejection | 99.5% | 99.5% | 99.5% | 99.5% | 99% | 99% |
| Membrane Area ft2(m2) | 95(8.8) | 400(37) | 95(8.8) | 400(37) | 95(8.8) | 400(37) |
| Testing Pressure | 225Psi | 225Psi | 225Psi | 225Psi | 150Psi | 150Psi |
| Max. Pressure | 600Psi | 600Psi | 600Psi | 600Psi | 600Psi | 600Psi |
| Nacl (Testing) | 2000ppm | 2000ppm | 2000ppm | 2000ppm | 2000ppm | 2000ppm |
| Temperature (Testing) | 25℃ | 25℃ | 25℃ | 25℃ | / | / |
| Max. Input SDI | 5 | 5 | 5 | 5 | 5 | 5 |
| PH (Testing) | 6.5~7 | 6.5~7 | 6.5~7 | 6.5~7 | 6.5~7 | 6.5~7 |
| Testing Time | 30min+ | 30min+ | 30min+ | 30min+ | 30min+ | 30min+ |
| Inlet Chlorine Concentration | 0.1ppm | 0.1ppm | 0.1ppm | 0.1ppm | 0.1ppm | 0.1ppm |
| Input Water Temperature | 5℃~45℃ | 5℃~45℃ | 5℃~45℃ | 5℃~45℃ | 5℃~45℃ | 5℃~45℃ |
| PH (Washing) | 2~10 | 2~10 | 2~10 | 2~10 | 2~10 | 2~10 |
Where Our RO Membranes Deliver Reliable Performance
* Municipal Drinking Water: Removing nitrates, arsenic, fluoride, and hardness from groundwater
* Industrial Process Water: High-purity feed for pharmaceuticals, electronics, and power generation
* Food & Beverage: Concentration, demineralization, and ingredient water production
* Seawater Desalination: Coastal communities, resorts, ships, and offshore rigs
* Wastewater Reclamation: Treating MBR or secondary effluent to reuse standards (e.g., irrigation, cooling)
* Boiler Feedwater: Preventing scale and corrosion in high-pressure steam systems




Compatibility & Installation of RO Membrane
Seamless integration with your existing RO system, our industrial reverse osmosis membranes are designed as direct replacements for leading brands:
* Compatible with DOW FILMTEC™, Hydranautics ESPA/ESNA, Toray TM, LG Chem, and GE membranes
* Standard 8040 (8" x 40"), 4040 (4" x 40"), and 2540 (2.5" x 40") dimensions
* Same O-ring placement, flow restrictor design, and connector type
* No system modification required-simply swap during maintenance
We provide full installation guidelines, startup procedures, and preservation instructions.
Why Choose Our RO Membranes?
* Lab-Validated Performance: Every batch is tested for flux and rejection before shipment
* Global Installations: 20,000+ elements operating in 20+ countries
* 24-Month Warranty: Against manufacturing defects and premature failure
* Free System Audit: Send us your RO data-we'll recommend the optimal membrane and predict lifespan
* Fast Global Shipping: In-stock elements shipped within 48 hours
* Sustainable Packaging: Recyclable materials, minimal plastic use
Get high-rejection, fouling-resistant membranes that last longer and save energy.
Request Free Membrane Selection & Quotation
FAQ
Q1: How long do RO membranes typically last?
A: With proper pretreatment (cartridge filters, antiscalant, dechlorination) and regular cleaning, most membranes last 3–5 years. Seawater elements may last 2–4 years due to higher stress. We offer a free lifespan calculator based on your feedwater analysis.
Q2: Can I replace a DOW FILMTEC™ membrane with yours?
A: Yes. Our BW30-400 is a direct performance equivalent to DOW BW30-400, with identical dimensions, flow, and rejection specs. Thousands of customers have successfully switched without system changes.
Q3: Do you offer membranes for high-silica or high-organic feedwater?
A: Absolutely. For challenging waters, we recommend our BW30FR-400 (Fouling Resistant) variant with enhanced surface hydrophilicity and smoother topography to reduce organic and colloidal adhesion. Pair it with our antiscalant dosing system for best results.