Industrial Reverse Osmosis System

Industrial Reverse Osmosis System
Details:
The industrial reverse osmosis system removes up to 90-99% of salt and contaminants from various impure feed water sources, including municipal water, brackish water, and surface water. The industrial RO system effectively blocks 99% of bacteria, particulate matter, sugars, proteins, dyes, and other impurities.
COYON offers a variety of prefabricated and customized industrial reverse osmosis systems with treatment capacities ranging from 500L to 50,000L/H. These energy-efficient industrial reverse osmosis plants meet diverse industrial water treatment needs and applications, producing high-quality water at an affordable price.
Send Inquiry
Download
Description
Technical Parameters

The industrial reverse osmosis system removes up to 90-99% of salt and contaminants from various impure feed water sources, including municipal water, brackish water, and surface water. The industrial RO system effectively blocks 99% of bacteria, particulate matter, sugars, proteins, dyes, and other impurities.

 

COYON offers a variety of prefabricated and customized industrial reverse osmosis systems with treatment capacities ranging from 500L to 50,000L/H. These energy-efficient industrial reverse osmosis plants meet diverse industrial water treatment needs and applications, producing high-quality water at an affordable price.

 

Our industrial reverse osmosis water systems are designed to meet the most demanding continuous operation and corrosive environment requirements, delivering high-quality water. These industrial RO plants are state-of-the-art systems, employing advanced engineering technology to provide cutting-edge solutions for the water treatment industry. They are also equipped with optional features, control characteristics, and add-ons, allowing users to customize their RO systems. Whatever your water treatment application needs, our industrial RO systems are the best choice.

Industrial Reverse Osmosis System
Industrial RO System

Compact Industrial Reverse Osmosis System

Our CY-RO-500L series industrial reverse osmosis systems are equipped with media filters and chemical dosing systems (pre-chlorination, scale inhibitor, dechlorination, post-chlorination, and post-pH adjustment). This equipment is primarily customized to meet individual customer needs and different water treatment applications. The CY-RO-500L series utilizes advanced energy-saving membrane technology and is one of the most compact industrial reverse osmosis systems on the market.

 

Containerized Industrial Reverse Osmosis System

COYON also offers fully containerized, mobile industrial reverse osmosis water treatment systems, assembled in ISO-compliant containers. Each container is customized for a specific water treatment application, making it easy to install and operate, and featuring high efficiency, small footprint, and energy savings.

 

Industrial Reverse Osmosis System Composition

 

• Raw Water Pump
• Quartz Sand Filter
• Activated Carbon Filter
• Chemical Dosing
• Softener
• 5μm Precision
• High-Pressure Pump
• Reverse Osmosis Membranes
• Automatic Backwash System
• UV Sterilizer
• Product Water Storage Tank
• Complete Pipeline and Fittings

Components of Industrial RO System 01
Components of Industrial RO System 02

Industrial Reverse Osmosis Water Treatment Process Flow

 

Raw water → original water tank → original water pump → multi-media filter (quartz sand filter)→ activated carbon filter → soft water processor → precision filter → high pressure pump → first stage reverse osmosis (RO) device → pure water tank → high pressure pump → second stage reverse osmosis → ultraviolet sterilization device → water point

 

Industrial Reverse Osmosis System

 

Cost-effective industrial RO systems utilize the latest reverse osmosis technology to remove dissolved salts, particulate matter, organic matter, minerals, tannins, solids, and other impurities from water. Industrial reverse osmosis system manufacturers use reverse osmosis membranes as their core separation technology to remove these impurities.

 

As part of our industrial product line, reverse osmosis (RO) units have processing capacities ranging from 500L to 50,000L/H. These RO units are available standard with pretreatment and post-treatment components. Furthermore, customization is available to meet specific customer needs, such as increasing feed water TDS concentration, lowering water temperature, reserving space for future expansion, using variable frequency drives (VFDs) in variable voltage designs, providing building management system (BMS) output interfaces, data logging, and remote monitoring.

 

Technical Data

 

Model

Productivity

(T/H)

Motor Power

(KW)

Recovery Rate

(%)

Outlet Water Conductivity

(us/CM)

Raw Water Conductivity

(us/CM)

CY-RO-500L

0.5

1.5

50

≤10

≤300

CY-RO-1000L

1

2.2

50

≤10

≤300

CY-RO-2000L

2

3

50-60

≤10

≤300

CY-RO-3000L

3

4.5

55-65

≤10

≤300

CY-RO-4000L

4

6.5

55-65

≤10

≤300

CY-RO-5000L

5

8

60-70

≤10

≤300

CY-RO-10000L

10

15

60-70

≤10

≤300

CY-RO-20000L

20

22

65-75

≤10

≤300

CY-RO-30000L

30

26

70-75

≤10

≤300

CY-RO-50000L

50

55

70-75

≤10

≤300

 

Industrial Reverse Osmosis System Selection Guide

 

To select the correct RO model, the following information must be provided:

1. Flow rate (L/hour, etc.)

2. Feed water TDS and water quality analysis: This information is crucial for preventing membrane fouling and helping us choose the correct pretreatment method.

3. Iron and manganese must be removed from the water before it enters the reverse osmosis unit.

4. Total suspended solids (TSS) must be removed before entering the industrial reverse osmosis system.

5. Feed water SDI value must be less than 3.

6. The water should be free of oil and grease.

7. Chlorine must be removed.

8. Available voltage, number of phases, and frequency (208, 460, 380, 415V)

9. Expected area dimensions for the industrial reverse osmosis system installation location.

 

Industrial Reverse Osmosis System Advantages

1

Can run and produce water continuously, highly automatic

2

No need chemical to regeneration,easy operation and maintainance

3

RO system uses imported DUPONT membrane

4

Automatic switch on when lack of water,and switch off when no water or full of water

5

RO membrane auto wash and reduce the pollution speed.

6

Low-pressure switch protects high-pressure pump from damage cause by water supply stops.

7

Production water condutivity meter monitors water quality online contionuosly.

8

Input water and dense water pressure meters, monitor the RO differential pressure and remind the time of washing.

 

Applications of Industrial RO System

 

* EDI Pretreatment

* Rinse Water

* Pharmaceutical Manufacturing

* Boiler Feedwater

* Laboratory Water Purification System

* Chemical Mixing

* Cooling Tower

* Ion Exchange Pretreatment

* Rainwater Treatment

* Well water treatment

* Food and beverage

* Ice making

* Oil refinery water treatment

* Nitrate removal from water

* Electronics/metal surface treatment

* Mining

* Beverage production and bottled water

* Spot-free product rinsing

 

 

Send Inquiry